Skip to content
Platform-ready

Changing Room & Staff Lockers

The proven steel locker, with smart access when you want it

Conventional full-height changing lockers in 2 to 24 compartments, built for wet areas and daily churn. Order them with mechanical latches at the lowest cost per compartment, or specify the same shells with electronic latches so the whole room can be brought onto the LockerLogic platform later without replacing a single cabinet.

Illustration of three banks of changing room lockers in grey, teal and amber finishes, showing 6-door, 9-door and 12-door compartment layouts

Quick answer: changing room & staff lockers in Singapore

Conventional full-height changing lockers in 2 to 24 compartments, built for wet areas and daily churn. Order them with mechanical latches at the lowest cost per compartment, or specify the same shells with electronic latches so the whole room can be brought onto the LockerLogic platform later without replacing a single cabinet.

Supplied with mechanical locks, or with electronic latches so the bank can join the platform at any time. Colour finishes are made to order in any quantity that justifies a powder-coat run — blues, greens, ambers, pinks and greys are all standard pigments. Wood-effect heat-transfer finishes are available where the room is front-of-house rather than back-of-house.

Standard configurations

These cover the large majority of enquiries and are the fastest and cheapest route to a delivered installation. Anything here can also be made to a different size.

Standard configurations and dimensions
Configuration Compartments W × D × H (mm) Notes
2-door 2 full-height 850–900 × 420–450 × 1800–1850
3-door 3 full-height 900 × 420–450 × 1800–1850
4-door 2 wide × 2 high 900 × 420–500 × 1850
6-door 3 wide × 2 high 900 × 420 × 1800
8-door 2 wide × 4 high 850–900 × 390 × 1800
9-door 3 wide × 3 high 900 × 400–420 × 1850
10-door 2 wide × 5 high 850 × 390 × 1800
12-door 3 wide × 4 high 900 × 350–390 × 1800
15-door 3 wide × 5 high 900 × 350–390 × 1800
18-door 3 wide × 6 high 900 × 350–390 × 1800
24-door 4 wide × 6 high 900 × 350–390 × 1800
Knock-down single column 4 or 6 high 450 × 400 × 1850 Ships flat and bolts together on site — for lifts and stairwells that will not take a welded bank

Dimensions are stated as width × depth × height in millimetres throughout this site. Factory drawings often mix conventions, so confirm against the dimensioned drawing issued with your quotation before any builder’s work is committed.

Made to order

Colour finishes are made to order in any quantity that justifies a powder-coat run — blues, greens, ambers, pinks and greys are all standard pigments. Wood-effect heat-transfer finishes are available where the room is front-of-house rather than back-of-house.

Construction & specification

  • Cold-rolled steel, 0.5–1.2 mm depending on panel and family, with welded or knock-down assembly
  • Electrostatic powder coat, phosphate-free — standard greys and off-whites, plus colour and wood-effect finishes to order
  • Louvred ventilation as standard; perforated doors or mesh backs where airflow matters more than privacy
  • Cam lock, padlock hasp, coin-return lock or electronic latch — specified per bank
  • Sloping tops to stop items being left on top of the bank, where housekeeping asks for it
  • Welded plinth or 100 mm legs so floors can be hosed and squeegeed underneath
  • Knock-down construction available for sites where a welded bank cannot be carried in

What goes in them

  • Staff uniforms, shoes and personal effects
  • Members' clothes during a swim or a class
  • Wet swimwear and towels
  • Contractor and housekeeping kit
  • Kitchen and F&B staff belongings
  • PPE and site boots

Keyless access

Supplied with mechanical locks, or with electronic latches so the bank can join the platform at any time.

How the platform works →

Changing lockers — questions we get asked

Can existing lockers be upgraded to keyless access instead of being replaced?

Usually, yes — and it is far cheaper than replacement. Most steel lockers can take a retrofit electronic latch in place of the existing cam lock, with a controller and keypad mounted at the end of the bank. We survey a sample door first, because latch geometry and door thickness decide whether the kit fits. Where a bank is too old, too thin-gauge or too corroded to hold a latch reliably, we will say so rather than sell a kit that will fail.

Which locker size suits a changing room?

For members changing for a class or a swim, 12 to 24 compartments per bank gives the most storage per metre of wall and suits day use where nothing stays overnight. For anything hung — uniforms, suits, golf bags — you need full-height 2, 3 or 4-door banks. A common answer in one room is a mix: full-height along one wall for members who store kit permanently, and high-density banks near the entrance for day use.

Will steel lockers rust in a Singapore wet area?

Powder-coated cold-rolled steel handles a changing room well, but standing water at the base is what eventually kills a locker. Specify a welded plinth or legs so the floor can be cleaned underneath, keep ventilation louvred rather than sealed, and avoid siting a bank where it takes direct spray from a shower head. For genuinely wet zones — poolside, dive rinse areas, marina pontoons — stainless steel or ABS is the right material and we will quote that instead.

Get a quote for changing room & staff lockers

Send the wall length available, the largest item that has to fit, and roughly how many people will use it. That is usually enough for an indicative figure before anyone visits — and we will tell you if a different family in the range suits you better.

Guo Jian Feng, Founder · GX TECH PTE. LTD. (UEN 202503838W) · trading as LockerLogic